Services
The perfect execution of all current backup options in structural fire protection
- on-site inspection and expert advice
- combination sealants
- Cable insulation
- Pipe Seals
- R90-fire cuffs
- pressing hard to reach openings, fire dampers and frames
- Installation and maintenance of fire dampers
- Fire protection coverings of all kinds (ventilation and smoke extraction channels, cable ducts, cable trays, etc.)
- Creation of fire walls and ceilings
- Fire protection cushions, fire bricks and plugs
- Proper documentation
Fire Blanket
A fire protection ceiling ensures the escape and rescue routes..
In most cases, electric supply lines and pipes are made of combustible and non-combustible materials below the soffit. Without a protective fire protection in the event of a fire blanket can fall these installations and thereby block escape routes and endanger human life.
Fire safety cushion
Fast sealing system – safe solution!
In the subsequent installation of cables, it is not uncommon that bulkheads are open for a long time. Schott systems that do not close automatically in case of fire in this time offer no protection. To prevent the spread of fire on these vulnerabilities, such openings can to repair, be temporarily sealed with fire protection inexpensive pillows.
Fire combination insulation
Cable and pipe penetration seals prevent the spread of fire and smoke.
Walls and ceilings of a building are crossed by supply and disposal lines. These penetrations are sealed with cable and pipe seals.
Fire protection ducts
The installation channel (I-Channel ) prevents the spread of fire from the channel in a cable fire and thus protects example Escape and rescue routes.
Cable channels are available in two variants. A distinction is made between an E-Channel for maintaining the function that protects the cable in the duct before an external fire.
Fire protection clothing of ventilation ducts
Ventilation ducts can deform in case of fire or even break off. The channels will be planked as protection against the heat of fire protection boards.
Fire protection boards maintain the operability of ventilation ducts.
Independent ventilation ducts
Independent ventilation systems can exist as single- ventilation ducts made of fire-resistant boards. This design complies with the fire protection requirements. (no steel channel required therefore independent)
Fire protection clothing
Protective clothing for structural steel parts
Although steel components are classified as non-combustible without specific proof, but lose their capacity already at a heating at 500 ° C. This temperature is reached after 5-10 minutes.
Special fire- protection panels receive the sustainability of steel components.
Protective clothing for timber structures
Wood is classified as easy, normal or low flammability.
A fire protective covering or coating reduces the flammability of the wood components.
Fire doors
Fire doors prevent the spread of fire and smoke on escape routes – the burning building can exit safely.
The means of escape shall be protected especially against fire and smoke. Fire doors divide into several fire escape routes. They are fire retardant and will also have to be open under extreme conditions.
Fire walls
In case of fire, a fire wall over a defined period must remain steadfast.
Fire walls divide a building into separate fire areas. Depending on static requirements, these can be run as a solid or as light partitions.
Fire protection gap
Fire joints prevent the spread of fire and smoke on combustible expansion joints.
Larger solid components are separated by expansion joints. To prevent the spread of fire and smoke through the combustible expansion joints, the joints are sealed with flame-retardant coating, fire protection materials or joint lines. (The actual function of the expansion is retained in full.)